top of page

Commercial HVAC Automation Case Study: Yoga Source Los Gatos

Maktinta designed an integrated energy and HVAC control system for Yoga Source Los Gatos, a 10,000 sq ft wellness facility with dramatically different temperature and humidity requirements throughout the day.

​

The project combines rooftop solar, battery storage, and custom HVAC automation to manage more than 12 daily condition changes while reducing grid dependence and maintaining precise indoor conditions for each class.

Client Background​

Yoga Source Los Gatos operates a 10,000 sq ft wellness facility offering hot yoga, non heated classes, and reformer based training. Each class requires a different indoor environment. Temperature, humidity, ventilation, and fresh air requirements can change substantially from one session to the next, creating a controls challenge that standard commercial thermostats were not designed to manage.

​

Maktinta had already worked with Yoga Source at other locations, giving the team direct experience with the operational requirements of the business.

Company: Yoga Source

Industry: Wellness and Fitness

The HVAC Control Challenge

The facility can require more than 12 temperature changes in a single day across multiple rooms.

A hot yoga class may require dramatically different temperature, humidity, ventilation, and exhaust conditions than the class immediately before or after it.

​

The system therefore needed to transition between environments quickly while maintaining comfort, indoor air quality, and energy efficiency without requiring staff to manually reprogram thermostats throughout the day.

Constraints

  • More than 12 daily temperature transitions

  • Temperature changes of up to approximately 50°F between classes

  • Humidity control

  • Fresh air and exhaust requirements

  • Multiple rooms operating on different schedules

  • Frequent weekly schedule changes

  • Need for remote monitoring and control

Custom HVAC Automation

Standard thermostats could not support the number of daily condition changes required by the facility.

Maktinta engineered a custom automation system that coordinates temperature, humidity, ventilation, exhaust, and scheduling across the studio.

​

Each class can be programmed around its required environmental conditions, allowing the system to prepare the room before the class begins and transition it for the next session automatically.

Facility staff can monitor and update the schedule remotely without physically reprogramming each thermostat.

Solar and Battery Integration

The HVAC controls were paired with an onsite solar and battery system designed to reduce grid dependence and support the facility's significant heating and cooling loads.

​

System details:

  • Facility: Approximately 10,000 sq ft

  • Solar PV 22 kW

  • Battery Storage: 40 kWh

  • Controls: Custom HVAC scheduling and automation

  • Monitoring: Remote temperature, humidity, occupancy, and system performance monitoring

  • Data: Cloud based performance and diagnostic storage

  • Backup: Battery support during short utility outages

Managing a Changing Indoor Environment

The system follows the studio's class schedule rather than relying on fixed thermostat periods.

Temperature and humidity targets are automatically adjusted for each class, while ventilation and exhaust systems respond to the requirements of the space.

​

Facility staff can monitor conditions remotely and make schedule changes from a connected device without rebuilding the control sequence manually. Overrides are intentionally limited to protect system stability and prevent unnecessary energy use.

​

Timeline

  • Design: 2 weeks

  • Permitting: 3 weeks

  • Installation: 4 weeks

  • Commissioning and Training: 1 week

Project Results

The completed system gives Yoga Source centralized control over temperature, humidity, ventilation, exhaust, solar generation, and battery storage while reducing the amount of manual intervention required from staff.

The automation system maintains the environmental conditions required for each class and allows ownership to monitor facility performance remotely.

​

  • 12+ Daily programmed environment changes

  • 40 kWh Battery storage

  • Remote Control: Temperature, humidity, scheduling, and system monitoring

​

The facility is projected to approach near zero annual electricity use as the solar, battery, and controls systems operate together.

Client Testimonial

We have been working with Maktina for over 10 years at our other studio locations so they were the natural choice as an HVAC Control system design and implementation partner. Creating the optimal temperature, humidity and air purity for Yoga classes is extremely complex and Maktinta were innovative in the solution and flexible to work with. We genuinely felt that Gal Moyal and his team were invested in the success of the project and the result has been the creation of a state-of-art system for HVAC scheduling, Temperature and Humidity control as well as Exhaust and Energy optimization. 

 

As a Yoga studio we are extremely sensitive to our environmental impact, Maktinta provided a Solar power system that supports our operation and not only provides costs saving but also protects us during the frequent short power outages experienced in our area.

​

Without hesitation I would recommend Maktina for Solar and Energy Control and Optimization solutions.

​

-Steve

Owner of Yoga Source

Key Takeaways

A quick overview of the project’s impact and the value Maktinta brought to the build.

Controls Built Around Operations

The system was designed around Yoga Source's actual class schedule rather than forcing the facility to operate within the limitations of standard thermostats.

Energy Systems Working Together

Solar generation, battery storage, HVAC controls, ventilation, and monitoring were treated as parts of one facility energy system.

Existing Client Knowledge

Maktinta's previous work with Yoga Source provided direct knowledge of the environmental requirements and operating patterns unique to the studios.

Managing a Facility With Complex HVAC Requirements?

Maktinta engineers HVAC controls, energy systems, solar, and battery storage around how commercial facilities actually operate.

​

If your building requires changing temperature, humidity, ventilation, or energy conditions throughout the day, we can help design the system around those requirements.

Follow

  • LinkedIn

Hybrid Liquid and Air Architectures

© 2024 by Maktinta Energy | Powered by Zema Marketing 

Most real facilities are mixed. Cold plate on the high-density rows, RDHx or contained air on the rest, sharing one chilled water plant. The difficulty is the plant: sizing, staging, and control across two very different load profiles without either side destabilizing the other. We design the plant and write the control sequences.

bottom of page